Packages: 23
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Particles/asbestos / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
fibers 1 | 0.01 fibre/cm3 |
Asbestos in air - Limits according to The Norwegian Labour Inspection Authority [A-2a-SANERING]
Package info
Price: 2.130 NOK / sampleStd. response time: 5 work days
Fastest response time: Sameday
Discount group: 1
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 600 L
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: ISO 14966
Express: Yes, Fastest delivery sameday ekspress: 300% addition, 09.00: 200%, 1d: 100%, 2d: 75%, 3d: 50%, 4d: 30%, 5d: 20%
Accreditation: Yes
Remarks: Se instruks for prøvetaking av abest i luft:
INSTRUKS
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Price is for analysis. Additional price for filter.
Lab: ALS Oslo
1 The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The method is accredited for the filter size Polycarbonate plates for SEM, 25 mm. Other filter sizes give unaccredited results.
Analysis of substance: | Report limit: |
---|---|
Particle determination, quantitative, on filter samples (concentration, size and type) [A-4a]
Package info
Price: 4.240 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Particle determination, qualitative, in material samples or on tape (identification of different particle types) [A-4b]
Package info
Price: 3.100 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 5-10 cm
Container: ALS Sampling tape + 2x zip bags(170x 230 mm)
Method: In-house method, SEM
Express: Yes
Accreditation: No
Remarks: The analysis is qualitative and is used to identify what particle types are presenr in dust (or material). The particles are divided into groups depending on their composition. This can be used to look for certain particles or find out the origin.
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
<1 µm | % |
1-2 µm | % |
2-5 µm | % |
5-10 µm | % |
10-20 µm | % |
>20 µm | % |
Particle size distribution [A-4c]
Package info
Price: 3.190 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is for particles in size generally being between >0.1 och <100 µm. For particle sizes outside this area other analysis are needed. The results are presented in table both in amount% and weight%
See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Volume (non accredited) | m3 |
Dust weight | 0.1 mg |
Dust weight, calculated | mg/m3 |
Total dust (total dust, respirable or inhalable), excl. filter [A-4d]
Package info
Price: 440 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 1 pc.
Container: Mixed cellulose 0.8 µm (total dust filter), 25 alt. 37 mm, weight [A-4d]
Express: No
Accreditation: No
Remarks: Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Quartz | 5 µg total |
Quartz in respirable dust on filter samples (FTIR) [A-5a]
Package info
Price: 795 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: In-house method, based on NIOSH 7602
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
Semi-quantitative SEM/EDS analysis [A-4e]
Package info
Price: 1.530 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: In-house method, SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is used to see what elements a material is constituted of. Elements with atom number lower than 6 can not be identified
Eksempel på hvordan en rapport kan se ut klikk her
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Inhalable dust | µg/m3 |
Quartz | µg/m3 |
Cristobalite | µg/m3 |
Tridymite | µg/m3 |
Total silica | µg/sample |
Respirable Crystalline Silica [A-5C]
Package info
Price: 3.880 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 400 liter
Container: PVC-filter 37 mm MW
Method: Respirable Dust by NIOSH 0600 mod., and Silica by NIOSH 7500 mod.
Express: No
Accreditation: No
Remarks: The analysis reported in µg/sample is accredited, while the calculation to µg/m3 is not accredited
Determination of quartz, tridymite and cristobalite as total silica and total respirable dust by XRF
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Salt Lake City
Analysis of substance: | Report limit: |
---|---|
Al | 0.1 µg total |
As, arsenic | 0.005 µg total |
Ba | 0.01 µg total |
Be | 0.0005 µg total |
Cd, cadmium | 0.0005 µg total |
Cr, chromium | 0.01 µg total |
Mo | 0.0005 µg total |
Ni, nickel | 0.005 µg total |
V | 0.001 µg total |
Zn, zink | 0.5 µg total |
Metals in total dust on filter [A-6t]
Package info
Price: 1.820 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Suitable filter: Mixed cellulose membrane filter in mointor. Size 25mm or 37mm
Price for individual elements: 750 NOK, then 250 NOK per element.
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: | Report limit: |
---|---|
Co | 0.0005 µg total |
K | 50 µg total |
Li | 0.01 µg total |
Mn | 0.005 µg total |
Na (sodium) | 5 µg total |
Pb, lead | 0.001 µg total |
Sn | 0.005 µg total |
Metals in inhalable dust [A-6i]
Package info
Price: 1.180 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: | Report limit: |
---|---|
Al | 0.1 µg total |
Cd, cadmium | 0.0005 µg total |
Ca | 2 µg total |
Cu, copper | 0.02 µg total |
Fe | 0.2 µg total |
Mn | 0.005 µg total |
Mo | 0.0005 µg total |
Pb, lead | 0.001 µg total |
V | 0.001 µg total |
Zn, zink | 0.5 µg total |
Metals in respirable dust [A-6r]
Package info
Price: 1.180 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Suitable filter. Filter for foravskiller, 37mm or 25mm, in monitor
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: | Report limit: |
---|---|
fibers 1 | 0.001 fibre/cm3 |
Asbestos in air - limits National Institute of Public Health [A-2a-FHI]
Package info
Price: 2.130 NOK / sampleStd. response time: 5 work days
Fastest response time: Sameday
Discount group: 1
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 1200 L
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: ISO 14966
Express: Yes, Fastest delivery sameday ekspress: 300% addition, 09.00: 200%, 1d: 100%, 2d: 75%, 3d: 50%, 4d: 30%, 5d: 20%
Accreditation: Yes
Remarks: Se instruks for prøvetaking av abest i luft:
INSTRUKS
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Price is for analysis. Additional price for filter.
Lab: ALS Oslo
1 The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The method is accredited for the filter size Polycarbonate plates for SEM, 25 mm. Other filter sizes give unaccredited results.
Analysis of substance: | Report limit: |
---|---|
Synthetic inorganic fibers | 4 fibres/mm^2 |
Synthetic inorganic fibers | fibre/cm3 |
Special fibres | 4 fibres/mm^2 |
Special fibres | fibre/cm3 |
Ceramic fibers | 4 fibres/mm^2 |
Ceramic fibers | fibre/cm3 |
Volume (non accredited) | L |
Fiber counting and identification in air [A-2a-FIBER]
Package info
Price: 2.520 NOK / sampleStd. response time: 10 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: recommended volume 150-400 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: MMMF, SEM
Express: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. The fiber types are: Synthetic inorganic fibres, cheramic fibres, special fibres, asbestos fibres.
Price is for analysis. Additional price for filter.
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Organic carbon | mg/m3 |
C-elementary (elementary carbon) | mg/m3 |
Total carbon | mg/m3 |
Organic carbon, Elemental Carbon and total carbon in diesel particulate matter
Package info
Price: 2.530 NOK / sampleStd. response time: 10 work days
Fastest response time: 7 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Container: 37 mm quartsfiber filter
Method: NIOSH 5040
Express: Yes, Fastest delivery 7 working days: 100%, 8 days: 75%, 9 days: 50%, 10 days: 30%, 11 days: 20%
Accreditation: Yes
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Salt Lake City