Packages: 119
Sample type: Air/Work environment
Analysis type: Particles/asbestos, Mold and dry rot fungus, Elements, Organic compounds, Microbiology, Other analyses, Combination packages, Contaminants
Particles/asbestos / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
fibers 1 | 0.01 fibre/cm3 |
Asbestos in air - Limits according to The Norwegian Labour Inspection Authority [A-2a-SANERING]
Package info
Price: 2.130 NOK / sampleStd. response time: 5 work days
Fastest response time: Sameday
Discount group: 1
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 600 L
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: ISO 14966
Express: Yes, Fastest delivery sameday ekspress: 300% addition, 09.00: 200%, 1d: 100%, 2d: 75%, 3d: 50%, 4d: 30%, 5d: 20%
Accreditation: Yes
Remarks: Se instruks for prøvetaking av abest i luft:
INSTRUKS
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Price is for analysis. Additional price for filter.
Lab: ALS Oslo
1 The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The method is accredited for the filter size Polycarbonate plates for SEM, 25 mm. Other filter sizes give unaccredited results.
Analysis of substance: | Report limit: |
---|---|
Particle determination, quantitative, on filter samples (concentration, size and type) [A-4a]
Package info
Price: 4.240 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Particle determination, qualitative, in material samples or on tape (identification of different particle types) [A-4b]
Package info
Price: 3.100 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 5-10 cm
Container: ALS Sampling tape + 2x zip bags(170x 230 mm)
Method: In-house method, SEM
Express: Yes
Accreditation: No
Remarks: The analysis is qualitative and is used to identify what particle types are presenr in dust (or material). The particles are divided into groups depending on their composition. This can be used to look for certain particles or find out the origin.
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
<1 µm | % |
1-2 µm | % |
2-5 µm | % |
5-10 µm | % |
10-20 µm | % |
>20 µm | % |
Particle size distribution [A-4c]
Package info
Price: 3.190 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is for particles in size generally being between >0.1 och <100 µm. For particle sizes outside this area other analysis are needed. The results are presented in table both in amount% and weight%
See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: | Report limit: |
---|---|
Volume (non accredited) | m3 |
Dust weight | 0.1 mg |
Dust weight, calculated | mg/m3 |
Total dust (total dust, respirable or inhalable), excl. filter [A-4d]
Package info
Price: 440 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 1 pc.
Container: Mixed cellulose 0.8 µm (total dust filter), 25 alt. 37 mm, weight [A-4d]
Express: No
Accreditation: No
Remarks: Lab: ALS Stockholm
Mold and dry rot fungus / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Spores | 7 fibres/mm^2 |
Mold- and spore content on filter [A-3g]
Package info
Price: 1.820 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Mold and dry rot fungus
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis can only be used to find out if there are spores in the air, not to specify the spores.
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Elements / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Hg, mercury | 0.02 µg total |
Mercury (Hg) on adsorption tubes [A-6c]
Package info
Price: 925 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Accreditation: Yes
Instruction: Sampling volume: 2 liters/min for 2 hours
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: | Report limit: |
---|---|
Cr(VI), Cr6+ | 0.25 µg total |
Cr(VI) on filter [Cr6-F]
Package info
Price: 960 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Method: EPA 425, ISO 16740
Express: No
Accreditation: Yes
Remarks: Se instruks for prøvetaking av inhalerbart støv for Cr6:
INSTRUKS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
Al | 0.5 µg total |
Ba | 0.03 µg total |
B | 0.5 µg total |
Fe | 1 µg total |
Li | 0.02 µg total |
Mo | 0.02 µg total |
P | 10 µg total |
K | 50 µg total |
Se | 2.4 µg total |
Na (sodium) | 10 µg total |
S | 50 µg total |
Te, Tellurium | 0.2 µg total |
Ti | 0.02 µg total |
Sn | 0.1 µg total |
Zn, zink | 1 µg total |
W | 0.04 µg total |
Metals in quartz fiber filter, additional elements[M-10-ADD]
Package info
Price: 1.820 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 1
Sample type: Air/Work environment
Analysis type: Elements
Method: SS-EN 14385:2004 mod. Digestion: The filter is digested by HNO3/HF/H2O2 in closed teflon vessels in microwave.
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Price for first element: 550 kroner
Price for each additional element 210 kroner
Lab: ALS Luleå
Analysis of substance: | Report limit: |
---|---|
Al | 0.1 µg total |
antimony (Sb) | 0.0005 µg total |
As, arsenic | 0.005 µg total |
Ba | 0.01 µg total |
Be | 0.0005 µg total |
B | 1 µg total |
Cd, cadmium | 0.0005 µg total |
Ca | 2 µg total |
Cs, cesium | 0.0005 µg total |
Cr, chromium | 0.01 µg total |
Co | 0.0005 µg total |
Cu, copper | 0.02 µg total |
Fe | 0.2 µg total |
Pb, lead | 0.001 µg total |
Li | 0.01 µg total |
Mg | 0.1 µg total |
Mn | 0.005 µg total |
Hg, mercury | 0.001 µg total |
Mo | 0.0005 µg total |
Ni, nickel | 0.005 µg total |
P | 0.2 µg total |
Pt, Platinum | 0.0005 µg total |
K | 50 µg total |
Se | 0.01 µg total |
Si | 20 µg total |
Ag | 0.02 µg total |
Na (sodium) | 5 µg total |
Sr | 0.5 µg total |
S | 2 µg total |
Tl | 0.0005 µg total |
Th | 0.0005 µg total |
Sn | 0.005 µg total |
Ti | 0.02 µg total |
W | 0.0005 µg total |
U | 0.0005 µg total |
V | 0.001 µg total |
Zn, zink | 0.5 µg total |
Zr | 0.01 µg total |
A-6-ADD Supplementary analytes
Package info
Price: 6.670 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Accreditation: No
Remarks: Price for individual elements: 750 NOK, then 250 NOK per element.
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: | Report limit: |
---|---|
Hg, mercury |
Mercury, Hg (low LOR) on absorption tubes [A-6c-low Mercury]
Package info
Price: 1.070 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: Yes
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Organic compounds / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
dichloromethane | 0.2 µg total |
1,1-dichloroethane | 0.2 µg total |
1,2-dichloroethane | 0.2 µg total |
1,1-dichloroethene | 0.2 µg total |
cis/trans-1,2-dichloroethene | 0.2 µg total |
1,2-dichloropropane | 0.2 µg total |
trichloromethane | 0.2 µg total |
tetrachloromethane | 0.2 µg total |
1,1,1-trichloroethane | 0.2 µg total |
1,1,2-trichloroethane | 0.2 µg total |
Chlorinated aliphatics in adsorption tubes [Menu A1]
Package info
Price: 2.245 NOK / sampleStd. response time: 10 work days
Fastest response time: 5 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: VDI 3865-3 (CS2-Ekstrakt, GC-MSD): 1998-06
Express: Yes, Fastest delivery 5 workdays, 100% addition.
Accreditation: Yes
Remarks: The analysis uses coal tubes and active sampling
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: | Report limit: |
---|---|
benzene | 0.2 µg total |
toluene | 0.2 µg total |
ethylbenzene | 0.2 µg total |
o-xylen | 0.2 µg total |
m/p-xylene | 0.2 µg total |
Aromatics in adsorption tubes [Menu A3]
Package info
Price: 2.850 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: in-house method, NIOSH.
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: Sample with SKC 226-01, flow 200 ml/min
See instructions for sampling with SKC AirChek Touch:
INSTRUCTIONS
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
n-hexane | 0.5 µg total |
n-heptane | 0.2 µg total |
n-octane | 0.2 µg total |
n-nonane | 0.2 µg total |
n-decane | 0.2 µg total |
n-undecane | 0.2 µg total |
n-dodecane | 0.2 µg total |
fraction >C6-C7 | 2.0 µg total |
fraction >C7-C8 | 2.0 µg total |
fraction >C8-C9 | 2.0 µg total |
fraction >C9-C10 | 2.0 µg total |
fraction >C10-C11 | 2.0 µg total |
fraction >C11-C12 | 2.0 µg total |
fraction >C12-C13 | 2.0 µg total |
Aliphatics in adsorption tubes [Menu A4]
Package info
Price: 2.010 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: In-house method, CS2-extract, GC-MSD
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: Måleusikkerhet (MU) 15 %
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
ethanol | 0.2-9 µg total |
1-propanol | 0.2-9 µg total |
2-propanol (Isopropanol) | 0.2-9 µg total |
1-butanol | 0.2-9 µg total |
2-butanol | 0.2-9 µg total |
ethylacetate | 0.2-9 µg total |
vinyl acetate | 0.2-9 µg total |
n-butyl acetate | 0.2-9 µg total |
isobutyl acetate | 0.2-9 µg total |
acetone | 0.2-9 µg total |
methylethyl ketone (MEK) | 0.2-9 µg total |
4-methyl-2-pentanone (MIBK) | 0.2-9 µg total |
cyclohexanone | 0.2-9 µg total |
benzene | 0.2-9 µg total |
toluene | 0.2-9 µg total |
ethylbenzene | 0.2-9 µg total |
sum of xylenes | |
styrene | 0.2-9 µg total |
Volatile organic compounds in adsorbtion tubes [Menu A5]
Package info
Price: 1.520 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: VDI 3865-3 (CS2-Ekstrakt, GC-MSD): 1998-06 and CS2-Ekstrakt, GC-MSD
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: | Report limit: |
---|---|
Aromatics >C8-C10 | 5000 µg/m3 |
aliphatics >C6-C8 | 5000 µg/m3 |
aliphatics >C8-C10 | 5000 µg/m3 |
aliphatics >C10-C12 | 5000 µg/m3 |
fraction >C6-C7 | 1000 µg/m3 |
fraction >C7-C8 | 1000 µg/m3 |
fraction >C8-C9 | 1000 µg/m3 |
fraction >C9-C10 | 1000 µg/m3 |
fraction >C10-C11 | 1000 µg/m3 |
fraction >C11-C12 | 1000 µg/m3 |
fraction >C12-C13 | 1000 µg/m3 |
n-pentane | 500 µg/m3 |
n-hexane | 200 µg/m3 |
n-heptane | 100 µg/m3 |
n-octane | 100 µg/m3 |
n-nonane | 100 µg/m3 |
n-decane | 100 µg/m3 |
n-undecane | 100 µg/m3 |
n-dodecane | 100 µg/m3 |
n-tetradecane | 100 µg/m3 |
n-tridecane | 100 µg/m3 |
n-hexadecane | 100 µg/m3 |
1,2,3-trimethylbenzene | 100 µg/m3 |
1,2,4-trimethylbenzene | 100 µg/m3 |
1,3,5-trimethylbenzene (mesitylene) | 100 µg/m3 |
1,2,4,5-tetramethylbenzene | 100 µg/m3 |
2-ethyltoluene | 100 µg/m3 |
3-ethyltoluene | 100 µg/m3 |
4-ethyltoluene | 100 µg/m3 |
4-phenylcyclohexene | 100 µg/m3 |
p-isopropyl toluene | 100 µg/m3 |
sec-butylbenzene | 100 µg/m3 |
styrene | 100 µg/m3 |
tert-butylbenzene | 100 µg/m3 |
n-butylbenzene | 100 µg/m3 |
n-propylbenzene | 100 µg/m3 |
benzene | 50 µg/m3 |
toluene | 50 µg/m3 |
ethylbenzene | 50 µg/m3 |
o-xylen | 50 µg/m3 |
m/p-xylene | 50 µg/m3 |
3-carene | 100 µg/m3 |
alpha-pinene | 100 µg/m3 |
beta-pinene | 100 µg/m3 |
alfa-terpinene | 100 µg/m3 |
limonene | 200 µg/m3 |
1,1,1,2-tetrachloroethane | 100 µg/m3 |
1,1,1-trichloroethane | 100 µg/m3 |
1,1,2,2-tetrachloroethane | 100 µg/m3 |
1,1,2-trichloroethane | 100 µg/m3 |
1,1-dichloroethane | 100 µg/m3 |
1,1-dichloro-1-propene | 100 µg/m3 |
1,2,3-trichloropropane | 100 µg/m3 |
1,1-dichloroethene | 100 µg/m3 |
1,2-dibromo-3-chloropropane | 100 µg/m3 |
1,2-dibromoethane | 100 µg/m3 |
1,2-dichloroethane | 100 µg/m3 |
1,2-dichlorobenzene | 100 µg/m3 |
1,2-dichloropropane | 100 µg/m3 |
1,3-dichlorobenzene | 100 µg/m3 |
1,3-dichloropropane | 100 µg/m3 |
1,4-dichlorobenzene | 100 µg/m3 |
1,2,3-trichlorobenzene | 100 µg/m3 |
1,2,4-trichlorobenzene | 100 µg/m3 |
2,2-dichloropropane | 100 µg/m3 |
2-chlorotoluene | 100 µg/m3 |
4-chlorotoluene | 100 µg/m3 |
bromobenzene | 100 µg/m3 |
tribromomethane (bromoform) | 100 µg/m3 |
bromochloromethane | 100 µg/m3 |
bromodichloromethane | 100 µg/m3 |
bromomethane | 100 µg/m3 |
chloroethane | 100 µg/m3 |
chloromethane | 100 µg/m3 |
cis-1,2-dichloroethene | 100 µg/m3 |
cis-1,3-dichloro-1-propene | 100 µg/m3 |
dibromochloromethane | 100 µg/m3 |
dibromomethane | 100 µg/m3 |
dichlorodifluoromethane | 100 µg/m3 |
dichloromethane | 100 µg/m3 |
hexachlorobutadiene (HCB) | 100 µg/m3 |
chlorobenzene | 100 µg/m3 |
tetrachloroethene | 100 µg/m3 |
tetrachloromethane | 100 µg/m3 |
trans-1,2-dichloroethene | 100 µg/m3 |
trans-1,3-dichloro-1-propene | 100 µg/m3 |
trichloroethene | 100 µg/m3 |
trichlorofluoromethane | 100 µg/m3 |
trichloromethane | 100 µg/m3 |
vinylchloride | µg/m3 |
2-Butanone | 100 µg/m3 |
hexanal | 100 µg/m3 |
acetone | 100 µg/m3 |
cyclohexanone | 100 µg/m3 |
4-methyl-2-pentanone (MIBK) | 100 µg/m3 |
1,4-dichlorobenzene | 100 µg/m3 |
2-methylhexane | 100 µg/m3 |
4-phenylcyclohexene | 100 µg/m3 |
cyclohexane | 100 µg/m3 |
isooctane | 100 µg/m3 |
methyl-tert-butylether (MTBE) | 100 µg/m3 |
ETBE | 100 µg/m3 |
2-ethyl-1-hexanol | 100 µg/m3 |
2-methyl-1-butanol | 100 µg/m3 |
isobutanol | 100 µg/m3 |
1-propanol | 100 µg/m3 |
1-butanol | 100 µg/m3 |
2-butanol | 200 µg/m3 |
2-propanol (Isopropanol) | 100 µg/m3 |
ethanol | 1000 µg/m3 |
isobutyl acetate | 200 µg/m3 |
n-butyl acetate | 200 µg/m3 |
tert-butyl acetate | 100 µg/m3 |
ethylacetate | 200 µg/m3 |
vinyl acetate | 100 µg/m3 |
naphthalene | 1000 µg/m3 |
Aromatics and halogenated volatile compounds (VOC) in air samples, large package (96 compounds) [Menu A7]
Package info
Price: 4.240 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: NIOSH
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Microbiology / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Yeast | 1 CFU/dish |
Moulds | 1 CFU/dish |
Mould and yeast by settle plate
Package info
Price: 165 NOK / sampleStd. response time: 8 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Microbiology
Accreditation: No
Instruction: Expose agar plate for air in 15 minutes
Remarks: Contact us for agar plates This results only gives a quantification of mould spores. If you are interested in a heftier air analysis, contact us
Store cool after sampling, should be delivered within 48 hours.
Lab: ALS Oslo
Other analyses / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
sulfur dioxide | µg total |
Sulphur dioxide (SO2) by IC - absorption solution
Package info
Price: 530 NOK / sampleStd. response time: 10 work days
Fastest response time: 2 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Other analyses
Sample amount: 100 ml
Method: CSN EN 1911, STN ISO 15713, CSN EN 14791, CSN EN ISO 10304-1
Express: Yes, Fastest delivery 2 workdays, 100% addition. 3 days: 75%, 4 days 50%
Accreditation: Yes
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
Attached special report |
Respirable dust on filter (cyclone extraction)
Package info
Price: 660 NOK / sampleStd. response time: 15 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Other analyses
Container: PVC-filter 37 mm MW
Method: NIOSH 0500
Accreditation: No
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Salt Lake City
Analysis of substance: | Report limit: |
---|---|
Air volume | m3 |
Total Inhalable Dust Fraction | mg |
Total Inhalable Dust Fraction | mg/m3 |
Silica | µg/filter |
Silica | mg/m3 |
All shift Average | mg/m3 |
Total dust by gravimetry (mg tot) + calculation (mg/m3) - working environment
Package info
Price: 1.650 NOK / sampleStd. response time: 10 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Other analyses
Container: Mix. cellulose Membranfilter 37 or 25 mm weighed
Method: Suite
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
hydrogen sulfide (H2S) | 0.01 mg/sample |
Hydrogen sulphide (H2S) by photometry - Absorption solution
Package info
Price: 1.100 NOK / sampleStd. response time: 10 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Other analyses
Sample amount: 100 ml
Container: Plastic
Method: CSN 83 0520-16:1978, CSN 83 0530-31:1980, CSN 83 4712 Nr. 3
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: | Report limit: |
---|---|
hydrogen sulfide (H2S) | 0.01 mg/sample |
Hydrogen sulphide (H2S) by photometry - Absorption solution - blank
Package info
Price: 1.100 NOK / sampleStd. response time: 10 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Other analyses
Sample amount: 100 ml
Container: Plastic
Method: CSN 83 0520-16:1978, CSN 83 0530-31:1980, CSN 83 4712 Nr. 3
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS CZ
Combination packages / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Attached special report |
Metals (25 Metals) and respirable dust on filter
Package info
Price: 1.930 NOK / sampleStd. response time: 15 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Combination packages
Container: PVC-filter 37 mm MW
Method: Suite
Accreditation: No
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Salt Lake City
Contaminants / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Hydrogen peroxide | 5 µg/sample |
Hydrogen peroxide in air
Package info
Price: 3.630 NOK / sampleStd. response time: 10 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Air/Work environment
Analysis type: Contaminants
Container: 25 mm quartz filter
Method: OSHA 1019
Express: Yes, Fastest delivery 4 workdays, 100% addition. 5 days: 75%, 6 days 50%
Accreditation: Yes
Remarks: Filters that are sent needs to be cool before and after sampling. Should be stored in the dark
Lab: ALS Salt Lake City